Free delivery

GGuestNot signed in
You're not signed in
LoginCreate account

11/16/2026 • Security

Zyxel GS1900 Switches: The June Patch That Didn't Close the Door

Zyxel has fixed a second pre-login flaw in its GS1900 small-business switches (CVE-2026-107441, CVSS 8.8), and switches that received June's security update are still exposed. Here is what happened, what is and isn't confirmed, and what to do.

If you updated a Zyxel GS1900 switch after June's security advisory, you did the right thing, and the switch still needs another update. On 3 November 2026 Zyxel published an advisory for a second flaw in the same part of the same firmware, and every firmware release that carried June's fix is affected by it.

The new flaw is tracked as CVE-2026-107441. It needs no username or password, and Zyxel rates it 8.8 out of 10 (High).

What happened, in plain English

The GS1900 is Zyxel's long-running family of web-managed switches for small offices. Like most switches in its class, you manage it through a built-in web page.

CVE-2026-107441 is an out-of-bounds write in the program behind that web page. In practice, a specially crafted web request can make the switch write data where it shouldn't, and Zyxel says an attacker could use this to "potentially execute OS commands" on the switch.

Three details matter here.

No login is required, but the attacker needs to be on your network. The CVSS vector Zyxel supplied is AV:A/PR:N. PR:N means no credentials are needed. AV:A means "adjacent": Zyxel's advisory describes a "LAN-based" attacker, so by this rating the request has to come from the local network and not from anywhere on the internet. That is a real limit. It is not much comfort if your guest Wi-Fi, a compromised PC or an unmanaged device can reach the switch's management page.

Ten models are affected. Zyxel's advisory lists the GS1900-8, GS1900-8HP, GS1900-10HP, GS1900-16, GS1900-24, GS1900-24E, GS1900-24EP, GS1900-24HPv2, GS1900-48 and GS1900-48HPv2, on firmware 2.90 Patch 2 (version strings ending .2)C0) and earlier. The fix is 2.90 Patch 3 (ending .3)C0). The NVD entry currently names only the GS1900-24E and is still marked "Awaiting Analysis", so use Zyxel's table as the model list.

The fix exists. According to BleepingComputer and Help Net Security, the patched firmware was released on 22 October, about two weeks before the advisory.

Why the June patch wasn't enough

On 16 June 2026 Zyxel patched CVE-2026-7273, a stack-based buffer overflow in the same web-management program. It has the same 8.8 score, the same ten models and the same no-login, same-network profile.

On 21 September, CISA added CVE-2026-7273 to its Known Exploited Vulnerabilities (KEV) catalogue, which means CISA has evidence of real attacks. Security outlets reported the same day that the threat-intelligence firm GreyNoise had tracked a campaign that compromised 996 GS1900 switches across 48 countries and collected device configurations, network details and hashed administrator credentials.

Then researchers at Binarly, whom Zyxel credits with reporting the new flaw, found a ready-made GS1900 exploit sitting on infrastructure linked to the same attackers. According to that reporting, the exploit:

  • worked against all ten firmware releases that already had June's fix;
  • relied on a different bug in the same program, which June's patch did not cover.

Binarly told Zyxel on 29 September. Zyxel treated it as a separate vulnerability, and that is CVE-2026-107441.

What is and isn't confirmed

  • CVE-2026-7273 (June) is confirmed exploited. It is on the CISA KEV list.
  • CVE-2026-107441 (November) is not on the KEV list. We checked the catalogue dated 13 November 2026. Zyxel's advisory says nothing about exploitation either way.
  • Press reports describe the new flaw as an exploited zero-day. That rests on the exploit being found on the attackers' infrastructure. It is strong circumstantial evidence, but not official confirmation.

Our read is to treat it as urgent without waiting for a catalogue entry. A working exploit in an attacker's hands, for a bug that outlived the previous patch, is reason enough.

The real lesson: a patch fixes a bug, not a component

It is natural to treat a security update as closing the matter: advisory read, firmware applied, job done. This story shows why that doesn't hold. A patch fixes the specific bug that was reported. It does not certify the rest of the code around it. Once one flaw in a component becomes public, researchers and attackers both start looking closely at that component, and follow-up flaws are common.

So for any device that has had a serious advisory, the working assumption for the next few months should be that there may be a second one. Check back.

Switches make this harder because they are easy to forget. They sit in a cupboard and work for years without attention. But a switch carries all the traffic in the office, and the configurations and credentials taken in the earlier campaign are the kind of information an intruder uses to move further into a network.

The honest bit

This is not a Zyxel-only problem. Incomplete fixes and follow-up CVEs have happened to nearly every networking vendor, including the brands we sell and like. Zyxel issued a patch within about a month of the report and credited the researchers.

One structural difference is relevant. With traditionally managed gear like the GS1900, a fix only helps once someone logs in to each device and installs it, and June's patch followed by November's shows how easily that falls behind. Cloud-managed platforms push firmware out on a schedule, which removes that step. They still have vulnerabilities, but the fix arrives without anyone having to remember it. We wrote about that trade-off in why a cloud-managed firewall keeps getting better after you buy it.

What we'd suggest you actually do

  1. Find your GS1900s and note the firmware version. It is shown in the switch's web interface. Compare the model and version against the table in Zyxel's advisory.
  2. Update to 2.90 Patch 3, even if you patched in June. If the version string ends in .2)C0 or lower, the switch is affected.
  3. Limit who can reach the management page. Put switch management on its own VLAN or restrict it to a few admin machines. It should not be reachable from guest Wi-Fi or general staff devices, and never from the internet.
  4. Change the admin password after updating. The earlier campaign collected hashed credentials. If your switch sat unpatched for a while, a new, unique password is cheap insurance.
  5. Check older models' support status. Zyxel says patches are only issued for models still within their vulnerability support period. If your GS1900 is an older variant that isn't in the table, confirm its status with Zyxel instead of assuming it is unaffected. We covered that risk in the danger of forgotten gear.
  6. Add switches to your patch routine. A quarterly reminder to check firmware on every network device, not only the firewall, would have caught both of these.

If you are not sure anyone would notice unusual activity on your network, our piece on whether your network can spot an intruder is a useful next read. For another recent case where one patch was not the end of the matter, see FortiBleed explained.

The friendly takeaway

There is no cause for panic. This flaw needs an attacker already on your network, a fix is available, and installing it takes a few minutes per switch. What it does require is a second look at a device you had reasonably ticked off in June.

If you would like a second pair of eyes on which switches you have, what firmware they are running or how your management access is set up, get in touch. We are happy to help, with no hard sell and no obligation.

References

Contact Us

Email: [email protected]

Phone: 1300 989 334

About

Your one-stop technology hub for all your networking, security, and IT needs. From cutting-edge networking solutions to robust security products, we provide everything your business requires to stay connected, secure, and efficient. Whether you're looking for advanced hardware, software, or services, we offer reliable, innovative technology tailored to help you build and protect your digital infrastructure.

Copyright © 2026 TYONLINE TECHNOLOGY PTY. LTD. All Rights Reserved.